StorageTek Host Software Component 6 User Manual

Page of 718
Chapter 4. Utility Functions   337
1st ed., 6/30/04 - 312579601
 
Invoking the Volume Report Utility 
Depending upon the environment in which it is being run, the Volume Report utility can 
be invoked in one of two ways:
• SLUVOLR EXEC (CMS)
• ACSUTIL SLKJCL file (SCP). 
SLUVOLR EXEC (CMS) 
The user can invoke the utility under CMS by running the SLUVOLR EXEC.
SLUVOLR fn ft fm 
where: 
fn, ft, fm
the parameter file description. If omitted, fn defaults to ‘‘SLUVOLR,’’ ft defaults to 
‘‘PARMS,’’ and fm defaults to ‘‘*.’’ No placeholders are allowed for unspecified 
parameters.
Parameter File 
A parameter file for the Volume Report running under CMS contains statements similar to 
those used to execute the utility under SCP. An example of a parameter file follows. 
PARM MIXED 
* SLSCDATA SLSCDATA DATA A 
SLSSCRPL SCRPOOL STMTS A 
SLSCNTL 160 DSN SLS200.SLSD.DBASEPRM 
SLSPRINT PRINTER 
SLSIN VOL(C84107) 
Under SCP, the user can invoke the utility by entering the following command: 
EXEC ACS UTIL VOLRpt 
Execution of the statement results in the ACSUTIL SLKJCL file:
ACSUTIL SLKJCL File 
 
/JOB   jobname  SLUADMIN 
/PARM  MIXED 
/FILE  SLSCNTL  DEV vaddr DSN control.set.name 
/FILE  SLSPRINT DEV PRNT CLASS A
/FILE  SLSVA    DEV vaddr DSN <control.set.name> VOL <volume.name> 
/FILE  SLSIN    * 
* VOLRPT ACS(ascid) LSM(lsmlist) 
* VOLRPT VOLSER(vol­list)
Volume Report