Appendix D. Logging ACS Robotics Motion   605
1st ed., 6/30/04 - 312579601
 
How Information is Logged 
The HSC periodically retrieves the statistics for robotics motions begun and temporary 
errors from the LMU. This information is logged to SYS1.LOGREC as software errors as 
shown in the Table 67. This record is a valid ‘‘Initiated and Temporary Error Motion 
Software Error Record’’ only under the following circumstances: 
• if the Record Type Field (bytes 642-643) has value X’6506’ and 
• the StorageTek identifier (X’FEEDFACE’ at bytes 644-647) is present. 
Such a record is called an LLG6 record. Refer to Appendix C, “Record Formats” on page 
497 
to see the record layout for LLG6. 
Table 67.  Format for Total Motions and Temporary Error Counts
Initiated and Temporary Error Motion Software Error Record
BYTE #
Description of Field
00-31
Standard HSC LOGREC header 
00-00
X’40’ indicates software detected error 
01-01 
X’80’ indicates VS2 or later release level 
02-02 X’08’ 
indicates 
TIME macro was used 
03-03 X’20’ 
indicates 
record contains an error ID 
04-05  
Reserved
06-06 Record 
count 
07-07 Reserved 
08-11  
System date of error
12-15 
System time of error 
16-23  
CPU ID
24-31  
Subsystem name
32-35  
Eyeball characters ‘LLG6’
36-41  
Proprietary data
42-43 Reserved 
44-44  
ACSid (binary)
45-45    