Programming and Operational Considerations 
The following are programming and operational considerations that should be observed if 
you have libraries resembling any of the illustrated configurations. The HSC permits 
operation of these library configurations provided that some programming and operational 
precautions are observed. 
These precautions are based on various functional restrictions described in following 
paragraphs. Table 80 lists the functions and the programming precautions that must be 
followed for associated configurations. 
Resolving CDS Issues After a Remote-Link Failure 
In configurations 3, 4, and 5, if there is a failure in the remote link while ACS1 has a 
hardware reserve issued against the primary CDS, ACS0 is locked out and is not able to 
perform any automated tape services until the reserve is released. This problem can 
happen even if the two ACSs are not remote-linked. 
The reserve can be released by disabling the remote-link interface. Operator intervention 
is required to disable the link. 
Restore Involving Journals from Channel-Extended Hosts 
In configurations 3, 4, and 5, if a restore of the control data set is needed, and the 
journaling option is invoked, all journal files must be obtained from every host that was 
included in the library LIBGEN. If all of the journals are not applied when the RESTore 
utility is executed, an accurate control data set may not be constructed during the restore 
operation. 
Obtaining all journals from remote-linked hosts can be a problem if the link is down. 
Consequently, not all journals can be obtained to fully satisfy a successful restore of the 
control data set. 
Careful planning must be done before executing the RESTore utility to ensure that 
journals are available from each host and that the remote link is fully operational when the 
restore operation is performed. 
Control Data Set Integrity
In configurations 3, 4, and 5, the primary control data set and the secondary control data 
set are separated across a remote link. If the link is interrupted, the secondary data set 
becomes the primary control data set for ACS1. 
Table 80.  Programming and Operation Precautions for Remote-linked Libraries
Function Applicable 
Configuration(s) 
Resolving CDS issues after a remote-link failure 
3 - 5 
Restore involving journals from channel extended 
hosts 
3 - 5 
Control data set integrity 
3 - 5