StorageTek Lifecycle Director DB2 Manager 312564001 User Manual

Page of 189
 
160 
DB2 Manager User Guide 
 StorageTek 
Proprietary 
 
 
Action:  Refer to IBM documentation for an explanation of the system abend 
code displayed in the message.  If no apparent cause for the problem 
can be identifier, report the error to your StorageTek customer support 
representative. 
 
 
OTD254xx – control region disk reader messages 
Messages from DB2 Manager control region disk reader tasks are written to the system 
log. 
 
OTD25401 
Invalid ODRH received on entry 
 Explanation:  An invalid reader task header control block has been encountered by 
a disk reader task during initialization processing.   Reader task 
initialization will be terminated. 
 
Action:  This condition indicates an internal error in DB2 Manager processing.  
Retain as much information about the error as possible and report the 
problem to your local DB2 Manager support representative. 
 
OTD25402 
Unable to get exclusive access to DISKREADER resource 
 Explanation:  A disk reader task has been unable to gain exclusive access to the 
disk reader request queue within 1 minute.   Processing of the request 
continues, but request queue integrity in the DB2 Manager control 
region may have been compromised. 
 
Action:  Examine the system log for other abnormal messages issued by the 
DB2 Manager control region.  If there is no apparent reason for the 
failure, contact your local DB2 Manager product support 
representative. 
 
OTD25403 
Unable to get exclusive access to ODRE resource 
 Explanation:  A disk reader task has been unable to gain exclusive access to the 
scheduler request queue within 1 minute.   Processing of the request 
continues, but request queue integrity in the DB2 Manager control 
region may have been compromised. 
 
Action:  Examine the system log for other abnormal messages issued by the 
DB2 Manager control region.  If there is no apparent reason for the 
failure, contact your local DB2 Manager product support 
representative. 
 
OTD25404 
Insufficient storage for workareas