Sterling Welder 882.01749.00 User Manual

Page of 93
882.01749.00  
12 
of 
93 
 
6.  EXTRUSION – “Simple”:  Connect the input cable (2-conductor cable-gray) to a dry 
  contact 
(zero voltage) 
signal that indicates the extruder 
  screw is turning. (
The connection in the controller should 
  be on terminal block #10 and PLC input X5..  A jumper wire 
  can also be installed on the same terminals (instead of a dry 
  contact.) if the feeder is to be started and stopped through the    
 feeder controller, and not with the extruder screw. 
 
7.   EXTRUSION – “Follower”:  Connect the input cable (2-conductor cable-gray) to a  
0-10 VDC, 0-20 mA, or 4-20 mA signal from the extruder 
that indicates the screw speed (rpm) of the extruder.
 (The  
    connection inside the controller should be on terminals blocks   
     51and  54.        
Feeder Configuration - Injection Molding: 
Touch the ACS logo on the main menu screen to access the configuration menu. See section # for 
details. 
 
 
   
 
   Feeder 
Type 
Selection. 
Select injection molding (default value). 
 
 
 
 
 
 
   
 
   Maximum 
Motor 
speed. 
Enter nominal motor speed.