Sterling Welder 882.01749.00 User Manual

Page of 93
882.01749.00  
20 
of 
93 
 
 
 
 
 
 
 
 
             Virgin material sensor. Select the no sensor, alarm only, or alarm & stop. 
 
Recipe Setup for Simple Extrusion:  
1.  Turn power switch to “ON” position.   
In order to calculate the correct motor speed required to feed the desired amount of additive, the following data 
must be entered: 
 
1)  Additive % 
2)  Throughput 
3)  Calibration weight. 
 
 
In addition, for the greatest accuracy, samples of the additive should be weighed and entered. 
 
Additive % 
 
 
 
 
The % additive specifies the proportion of additive to virgin material as a percentage of throughput. 
For example, if the throughput is 200 grams per minute and 8.5 grams of additive are required, the additive 
percentage would be 4.25. After the additive value has been entered, press the “Next” button to navigate to the 
Throughput screen.