            Extrusion - Constant:      Wire the “cycle/run” cable (two- conductor gray cable) to a set of 
dry (NO VOLTAGE) contacts that CLOSE when the screw rotates. (See Figure 5.) 
The connection 
inside the controller should be on terminal block #10 and PLC input X5.  
 
 
Extrusion - Proportional:     Wire the “cycle/run” cable to the extruder signal output that is 
proportional to the extruder speed. The signal can be 0-10 VDC or 0-20 mA or 4-20 mA.  Jumpers J1 
and J2 should be installed for 0-20mA or 4-20mA, and removed for 0-10VDC.   
 
NOTES:    1.  Signal voltage from the extruder must to be isolated.  Consult factory for 
            other signal requirements.  External signal converter may be required. 
 
2.  “Zero” input corresponds to zero screw speed and no additive dosing. 
“Maximum” input corresponds to maximum screw speed. 
 
 
 
 
 
 
TB #51 
 
     _ 
 
 
 
 
 
 
 
 
TB #54  
 
     + 
 
 
 
 
     0-10 VDC or 0/4-20 mA 
 
 
     Extruder output 
 
   Digital Dosing controller 
 
      Figure 6.  Analog Extruder Input Connection Diagram –                                       
                                Extrusion - Proportional