Maintenance 12
5.2.2. Adjusting the flap switch
Remove the connecting plug “flap switch”
from the connection housing of the hopper.
Connect an ohmmeter to PINS 2 and 3 of
the connecting plug “flap switch”.
Release the nuts (A) of the flap switch (B)
until the support can be displaced.
Open the outlet flap (C) so far that the front
tip of the outlet flap is approx. 30 mm (1.2")
away from the sealing surface.
Displace the flap switch (B) until the
contact of the magnet switch is closed.
Tighten the nuts (A) of the flap switch.
Check the adjustment:
In case of free hanging outlet flap (empty
hopper loader) the contact of the magnet
switch must be closed.
If the outlet flap cannot be properly adjusted, replace the flap switch or the outlet flap with
magnet.
Install the hopper.
&
 
Order numbers
switch with plug:
ID 28839
outlet flap with magnet:
ID 23093
Figure 1: Outlet flap