Simrad AUTOPILOT SYSTEM AP50 User Manual

Page of 188
 Installation 
20221032B
 89 
4.10 Drive Unit Installation 
The relation between drive units, drive unit voltage, input 
voltage, drive output, and interfacing to steering gear are shown 
in Table 4-2 and Table 4-3. The AP50 system detects whether a 
reversible motor or a solenoid is connected and outputs the 
correct drive signal automatically. 
Refer to the connecting diagrams for the different drive units on 
pages 91 through 93. 
Installation instructions for the drive units are found in the 
manuals for the individual units. 
The maximum drive current capabilities of the J50 and J50-40 
Junction Units are different. Use the table below as a reference 
and observe the notes. 
HYDRAULIC PUMPS 
 RAM 
CAPACITY 
 
   
MODEL MOTOR 
VOLTS 
JUNCTION 
UNIT 
 
MIN. 
cm
(cu. in.) 
 
MAX. 
cm
3
  
(cu. in.) 
FLOW 
RATE AT 10 
bar 
cm
3
/min. 
(cu. in./min.)
MAX. 
PRES-
SURE 
bar 
PWR. 
CONSUMP-
TION 
RPU80 
12 
J50 
80 (4.9) 
250 (15.2) 
800 (49) 
50 
2,5-6 A 
RPU160 
12 
J50 
160 (9.8) 
550 (33.5) 
1600 (98) 
60 
3-10 A 
RPU200 
24 
J50 
190 (11.6) 
670 (40.8) 
2000 (122) 
80 
3-10 A 
RPU300 
12 
J50-40 
290 (17.7) 
960 (58.5) 
3000 (183) 
60 
5-25 A 
 RPU300 
24 
J50 
290 (17.7) 
960 (58.5) 
3000 (183) 
60 
2,5-12 A 
RPU3 
24 
J50 
370 (22.4) 
1700 (103) 
3800/5000
(232/305) 
40 7-22 
RPU1 
12 
J50 
140 (8.5) 
600 (36.6) 
1400/2000
(120/185) 
40 7-22 
Steering Gear Interface: Hydraulic Plumbing 
Table 4-2  Hydraulic Pumps