Sentry Industries 5000 User Manual

Page of 130
SMC
 sierra monitor corporation 
Sentry Instruction Manual - Version 6 
 
APPENDIX A - SPECIFICATIONS
 
Page:  86 
C.  PERFORMANCE 
 
 
 
Combustible Gas (5100-02) 
 
  Range: 
0 - 99% Lower Explosive Limit. 
 
  Operating Temperature  -40
o
F to 158
o
F (-40
o
C to 70
o
C) 
 
  Relative Humidity 
5 - 99% RH 
 
  Accuracy: 
+/- 3% of Full Scale or 
 
   
+/- 10% of Applied Concentration 
 
  Response: 
Step to 50% within 10 seconds 
 
   
Recover to 10% within 45 seconds 
 
  Calibration Frequency 
Monthly, Recommended 
 
  Zero Drift: 
Less than 5% per year. 
 
  Typical Life: 
3 years in normal service. 
 
  Warranty: 
1 year. 
 
Hydrogen Sulfide (5100-05) 
 
  Range: 
0 - 100 PPM 
 
  Operating Temperature  -40
o
F to 122
o
F (-40
o
C to +50
o
C) 
 
  Relative Humidity 
10 - 99% RH 
 
  Accuracy: 
+/- 2 PPM 
 
  Response: 
<30 seconds to 50% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
3 years in normal service 
 
  Warranty: 
1 year 
 
   
 
Note: 
Only Combustible Gas (5100-02) and Electrochemical 
sensor Hydrogen Sulfide (5100-05) are FMRC Approved
 
 
   
 
 
Hydrogen Sulfide (5100-01) 
 
  Range: 
Factory 100 PPM, Max. 100 PPM 
 
  Operating Temperature  -40
o
F to 158
o
F (-40
o
C to 70
o
C) 
 
  Relative Humidity 
5 - 99% RH 
 
  Response: 
<60 seconds to 90% indication 
 
  Calibration Frequency 
Monthly, Recommended 
 
  Zero Drift: 
Less than 5% per year.  
 
  Typical Life: 
3 years in normal service.  
 
  Warranty: 
1 year. 
 
Oxygen (5100-03) 
 
  Range: 
Factory 25% O
2
, Max. 25% O
2
 
 
  Operating Temperature  -19
o
F to 122
o
F (-7
o
C to 50
o
C) 
 
  Relative Humidity 
5 - 99% RH 
 
  Response: 
10 seconds to 90% indication. 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 5% per year. 
 
  Typical Life: 
1 year in normal service. 
 
  Warranty: 
1 year 
 
Carbon Monoxide (5100-04) 
 
  Range: 
Factory 500 PPM, Max. 2,000 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<25 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
2 years in normal service 
 
  Warranty: 
1 year 
 
   
 
 
Chlorine (5100-06) 
 
  Range: 
Factory 10 PPM, Max. 100 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<60 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
2 years in normal service 
 
  Warranty: 
1 year 
 
Hydrogen (5100-07) 
 
  Range: 
Factory 1,000 PPM, Max 2,000 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<30 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
2 years in normal service 
 
  Warranty: 
1 year 
 
Sulfur Dioxide (5100-10) 
 
  Range: 
Factory 100 PPM, Max 100 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<20 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
2 years in normal service 
 
  Warranty: 
1 year 
 
Nitrogen Dioxide (5100-12) 
 
  Range: 
Factory 20 PPM, Max 100 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<35 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
2 years in normal service 
 
  Warranty: 
1 year 
 
Carbon Monoxide (5100-13) 
 
  Range: 
Factory 1,000 PPM, Max 2,000 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<25 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 2% per month 
 
  Typical Life: 
3 years in normal service 
 
  Warranty: 
1 year 
 
Carbon Monoxide (5100-16) 
 
  Range: 
Factory 2,00 PPM, Max 4,000 PPM 
Tolerates Hydrogen to 2,000 PPM 
 
  Operating Temperature  4
o
F to 122
o
F (-20
o
C to 50
o
C) 
 
  Relative Humidity 
15 - 99% RH 
 
  Response: 
<35 seconds to 90% indication 
 
  Calibration Frequency 
90 Days, Recommended 
 
  Zero Drift: 
Less than 1% per month 
 
  Typical Life: 
2 years in normal service 
 
  Warranty: 
1 year