4.5  Console Port Wiring 
 
A RS232 console port for configuration and management of the device is located on the LED 
display module shown in Figure 13. This port is intended to be a temporary connection during initial 
configuration or troubleshooting and allows for direct access to the serial-based management 
console. The connection is made using the DB9-Female to RJ45 console cable included in the 
device packaging shown below. Console connection settings are 57600 baud, no parity bits, 8 data 
bits, and 1 stop bit. 
 
 
 
Figure 13:  Console port location on display board 
Figure 14:  Console cable 
 
For user reference, the console cable pin-out is show in the table below. 
 
RuggedCom RS232 over RJ45 pin-out specification 
Signal Name (PC is DTE) 
Female DB9 
Male RJ45  
DCD – Carrier detect 
TxD – Transmit Data 
RxD – Receive Data 
DTR – Data terminal ready 
Signal GND 
DSR – Data set ready 
1* 
RTS – Ready to send 
CTS – Clear to send 
RI – Ring Indicator 
1* 
Table 4:  RS232 over RJ45 console cable pin-out 
 
After initial configuration, the RS416 can be configured via a number of mechanisms such as 
Telnet, and the built-in web server. Consult the RuggedSwitch ROS User Guide for further details. 
 
NOTE: This port is not intended to be a permanent connection and the cable shall be less than 2m 
(6.5 ft) in length.