Regency FireWizard User Manual

Page of 20
 
FPI FireWizard
TM
 Remote Control Manual              
 
Page 11                
                              
                                                                                                                                
 
AUTO MODE 
 
In Auto Mode the remote will adjust the flame setting and fan speed according to the 
temperature difference between the Set Temperature and the Room Temperature. 
 
When the set temperature is higher than the room temperature by more than 
2.5°C (4.5°F), the flame will be at the highest setting (7) and the fan speed will 
default to the lowest setting (1). 
As the set temperature approaches room temperature, the flame level will reduce 
accordingly. When the set temperature is equal to the room temperature, the 
flame will stay at the lowest setting, and the fan will turn off. 
Once the room temperature is higher than the set temperature by 2°C (3.6°F), the 
flame will turn OFF. 
 
Auto  mode can be selected by pressing and releasing the AUTO/MAN button until the 
symbol “AUTO” is shown on the LCD.  
In Auto mode, when either the “+” or “-” button is pressed, the Set Temperature will be 
displayed on the LCD instead of the Room Temperature. The Set Temperature will 
remain displayed on the LCD for 5 seconds after the button is released and then the 
display will revert to show the Room Temperature. The Set Temperature can be adjusted 
while it is displayed using the “+” and “-” buttons. 
The LCD will show the following when either the “+” or “-” button is pressed: 
 
Room 
Temperature
Set 
Temperature
Auto Mode normal 
display 
When “+” or “-” 
button is pressed