TROUBLESHOOTING 
 
If you are having problems with this unit, refer to these troubleshooting hints. Also, refer to the connection diagram 
to ensure your devices are connected properly.  
 
 
           Problem                                                                 Suggested Action 
 
I have no lights and no 
function at all. 
Check the fuse and main power. Replace the fuse if required with the correct rated fuse. 
Check the equipment connected to the CGC-1e for problems and/or short circuits. 
 
The fuse continues to 
blow. 
If the fuse blows repeatedly, verify the devices connected to the unit are working properly and that they 
are not too large for the CGC-1e to safely control. 
You may need to consider using expansion modules, (UPM / HPR / MLC) to decrease the amperage 
(load) on the CGC-1e fuse. 
 
My CO2 outlet never 
comes on. 
Verify the PPM-1c jumper or the PPM-1c is connected.  
 If the Exhaust outlet is ON, the CO
2
 will not be allowed to run. Turn up the Temperature and Humidity to 
a higher setting.  
In order for the CO
2
 outlet to function, the timeclock must be in “Daytime” mode. The CO
2
 is only 
activated when the lights are “ON”. 
 
The fans are running 
so often, the CO2 is 
hardly ever ON. 
You may have too much heat building up in your area or too small of an exhaust fan. Reduce the heat 
sources or increase your fan size.  
You may also consider using a “closed-loop” air conditioner to keep the temperature and humidity below 
the set points so that CO
2
 is allowed to run for longer amounts of time. 
 
My CO2 consumption 
seems to be quite high.  
Make sure your area is sealed. You may want to install a motorized damper to seal your exhaust fans 
when they are “OFF”. Even though the CGC-1e operates a standard “timed-release” sequence, you may 
still be “wasting” CO
2
If you are operating compressed CO
2
 valves, consider purchasing the optional PPM-1c “Part-Per-Million” 
sensor to upgrade to PPM control. The PPM-1c offers a significant improvement in CO
2
 efficiency. 
 
 The 
CO2 
level 
“overshoots” the PPM-
1c set point 
considerably.  
Small areas need less “Inject Duration” time than do larger areas. Larger areas need more “Inject 
Frequency” time in order to give the CO
2
 time to “mix” properly with the ambient air and measured by the 
PPM sensor.  
Start with lower CO
timer settings for small areas and increase the timer settings for larger ones.  
 
The Hydro pumps are 
not cycling properly. 
The Hydro pump outlets can be operated 24-hours a day or only when the “Lights” are “ON”. The “Hydro” 
selector switch also has a center “OFF” position, which can be used to “reset” the timing function. Make 
sure the switch is not turned “OFF”. 
 
 
 
 
MAKING CONNECTIONS 
 
 All of the main functions controlled by the CGC-1e are accessed using (8) standard 120 VAC, 15-amp receptacles mounted on 
the sides of the enclosure. This allows you to simply “plug in” any standard device without hardwiring or hassles. Printed 
labels on the front face of the enclosure identify the receptacles. 
 We highly recommend using only 3-wire devices with a ground. Suitably double-insulated devices are acceptable. Keep in 
mind that the combined amperage draw on all of the devices connected to the CGC-1e must be less than 15-amps @ 120 VAC.