Tri-M Systems REB 2000 User Manual

Page of 6
 
 
 
Tri-M Systems Inc., 6-1301 Ketch Court, Coquitlam, B.C. V3K 6X7, Canada 
Phone: (604) 527-1100, (800) 665-5600 Fax: (604) 527-1110 
Email: info@tri-m.com Web: www.tri-m.com 
3
 
7.  What are the differences among REB-2000 series? 
Ans: 
 REB-2000 
REB-2100 
Dimension (LxWxH) 
30 x 30 x 8 mm 
40 x 31.5 x 6.5 mm 
Connector   
12 pin header /Down 
RF Connector 
Female MMCX / UP 
Weight (g) 
8.6 
Channels 12 
Frequency L1, 
1575.42MHz 
Protocol 
NMEA 0183 GPGGA, GPRMC, GPGSA, 
GPGSV, GPGLL, GPVTG, 9600,8,N,1 
Voltage 3.3V±10% 
Maximum current 
170mA 
Average current in trickle 
power mode 
65mA 
Reaquisition time 
0.1sec. 
Hot start (average) 
8sec. 
Warm start (average) 
38 sec. 
Cold start  (average) 
48 sec. 
Accuracy 
25m CEP w/o S.A. 
Differential input 
RTCM 104 DGPS 
WASS Demodulator 
Yes 
Interface TTL,9600,8,N,1 
Update Rate 
1Hz 
Trickle power 
30% duty cycle 
Operation Temperature 
-40 ~ +85℃ 
Storage Temperature 
-40 ~ +85℃ 
Operating Humidity 
95% Non-condensing 
Maximum Altitude 
18000m 
Maximum Velocity 
515m/s 
Maximum Acceleration 
4G