Tri-M Systems REB 2000 User Manual
Tri-M Systems Inc., 6-1301 Ketch Court, Coquitlam, B.C. V3K 6X7, Canada
Phone: (604) 527-1100, (800) 665-5600 Fax: (604) 527-1110
Email: info@tri-m.com Web: www.tri-m.com
3
7. What are the differences among REB-2000 series?
Ans:
REB-2000
REB-2100
Dimension (LxWxH)
30 x 30 x 8 mm
40 x 31.5 x 6.5 mm
Connector
12 pin header /Down
RF Connector
Female MMCX / UP
Weight (g)
8.6
Channels 12
Frequency L1,
Frequency L1,
1575.42MHz
Protocol
NMEA 0183 GPGGA, GPRMC, GPGSA,
GPGSV, GPGLL, GPVTG, 9600,8,N,1
Voltage 3.3V±10%
Maximum current
Maximum current
170mA
Average current in trickle
power mode
power mode
65mA
Reaquisition time
0.1sec.
Hot start (average)
8sec.
Warm start (average)
38 sec.
Cold start (average)
48 sec.
Accuracy
25m CEP w/o S.A.
Differential input
RTCM 104 DGPS
WASS Demodulator
Yes
Interface TTL,9600,8,N,1
Update Rate
Update Rate
1Hz
Trickle power
30% duty cycle
Operation Temperature
-40 ~ +85℃
Storage Temperature
-40 ~ +85℃
Operating Humidity
≦
95% Non-condensing
Maximum Altitude
18000m
Maximum Velocity
515m/s
Maximum Acceleration
4G