Toshiba Magnia Z300 User Manual

Page of 270
233
Remove the sever panels, power supply unit and board for 
wireless card, and return the jumper switch to 3-4 short.
Install the board for wireless card, the power supply unit and 
server panels.
Connect the AC power cable again and restart your server.
10 Start the BIOS Setup Utility, set System Time and System 
Date and select “Load Setup Default” from the Exit menu to 
execute it.
NOTE: The standard settings displayed after the original data 
has been cleared are the initial data of the motherboard, and 
they may differ from the defaults (recommended settings).
When the original data is cleared, password of the security 
menu and data settings of the SCSI controller will also be 
cleared.
Before clearing information, remove all expansion cards.
Recovery Boot 
Perform the following operations if the recovery boot is needed:
Disconnect AC power cable.
Remove the server panles, power supply unit and board for 
wireless card.
Set the jumper switch PJ723 on the motherboard of the server 
to 2-3 short.
PJ723: 
2-3 short ... Recovery Boot.
1-2 short... Normal Boot
Install the board for wireless card, power supply unit and 
server panels, and connect the AC power cable.
Insert BIOS Recovery Diskette into floppy disk drive and turn 
on the server. The recovery process will take a few minutes.