Test-Um VALIDATOR-NT NT955 User Manual

Page of 97
56
Test-Um NT955 Series
Test Results
Untitled1.job
Test-Um Inc.
validator
A
B
C
D
BERT Results:
188ft
186ft
--
--
--
--
Length
Max: 300ft
Skew
Max: 35ns
SNR
Min:20db
BACKSPC
PG UP
PG DOWN
--
--
30.0
30.0
Short
100%
2005 Aug 25
  10:53:01
184ft
7 ft
Figure 4.4 Page Down to Display Distance To Short
Miswire - A wire or both wires of a pair are not connected to correct 
pins at the other end of the cable.  For example, a reverse pair displays 
the wires connected to the correct pair of pins, but the two leads are 
reversed.  (See Figure 4.5)
Test Results
Untitled1.job
Expected
Results
1                         1
2                         2
3                         3
6                         6
4                         4
5                         5
7                         7
8                         8
Cable001
Fail
1                         1
2                         2
3                         3
6                         6
4                         4
5                         5
7                         7
8                         8
Test Time: 10:53  Thu 2005  Aug 25              
BACKSPC
PG UP
PG DOWN
Test-Um Inc.
validator
100%
2005 Aug 25
  10:53:01
CAT5E
1 Gbit/s
Remote ID: 1
Figure 4.5 Test Results-Miswire
Split Pair - The cable has an error in the twisting of the wires together 
within the cable.  Cables are generally made up of 8 wires twisted 
together in 4 pairs.  A cable can be wired with correct continuity, but 
not with correct pairing.  If the only error is a split pair error, the cable 
has correct continuity.  If the Validator main unit is unable to link to its 
remote due to another error, such as a short,  A Link Test Error Message 
displays “Unable to Measure SNR.”  Press OK to view the wiremap 
results. (See Figure 4.6)
Validator
TM
 How AutoTest Works