Test-Um VALIDATOR-NT NT955 User Manual

Page of 97
70
Test-Um NT955 Series
Placing Tone On a Cable Pair
1.  Select 
Manual Tests. Choose Data, Phone or 2-wire cable 
type
2.  The Manual Test Menu for the cable type you selected displays.
3.  Select 
Tone.
4.  Select the desired 
Tone Sound.  Press Accept.  The cursor 
moves to the Tone Path dialog box. (Figure 5.6)
5.  Select the 
Tone Path by choosing the cable pair or pairs you 
wish to apply Tone to.  Press Accept.
6.  Using the appropriate cable assembly, connect the cable to the 
Main unit jacks.
7.  Press the 
Send (F1) soft key to start the tone. 
8.   Using a Tone Tracer, such as Test-Um’s TT100, trace the tone.
SEND
Tone Sound:
Data Tone
Untitled1.job
High - Low
Tone Path:
Press send to begin.
all
Test-Um Inc.
validator
100%
2005 Aug 25
  10:53:01
Figure 5.6 Tone Generator
Validator
TM
 Running Manual Tests