Electrical:
Voltage
Power
Air Flow 
Operation
Insulation Value of
Closed Doors
Weights
Top Housing
Lower Housing
115 VAC 60Hz
(High Speed) 450 Watts
(Low Speed) 340 Watts
High Speed 3400 CFM
Low Speed 1900 CFM
30 second Door Cycle Time
(Open-Close)
MODEL GH: R-22
MODEL GHD: R-38 
Whole House Ventilator: 48 Lbs.
Shipping: 67 Lbs.
26 1/4” long x 26” W x 14 1/8’ H
25 7/8” long” x 29 1/2” W 
x 13 5/8” H
specificationS
wiring
WARNING:
State and local 
electrical codes may require
that the GHOST be installed 
by a licensed electrician.
Check with your local code 
officials before installing. 
Be sure to turn off power 
before wiring the GHOST
Whole House fan.
Figure 6.
Figure 7.
6. Rotate the upper housing until it lines up with the
lower housing.  Make sure the edges of the two hous-
ings mate all the way around the GHOST (Figure 6)
and then pull the black attachment handles down over
their attachment posts (Figure 7). 
7. If desired, secure the GHOST to the top of the joists.
8. Plug the connector from the GHOST into the Control
Box.  Plug  the  Control  Box  into  an  unswitched,
grounded receptacle.
9. Install the ceiling grille (screws provided).
10. Check the unit for proper operation:
Turn the unit on - it will take 30 seconds for the
doors to open.
Fan  starts  -  the  fan  should  start  and  run
smoothly.
Be sure at least one window is open when the
fan is operating.