Chapter 2 Installing the Device
18
User’s Guide
The DC power supply, power switch, grounding screw, and terminal blocks, are located on 
the faceplate of the power supply unit.
To connect the DC power supply to a grounding point at your site:
1.
Remove the hex nut on the grounding screw.
2.
Place the ground lug on the screw and tighten the hex nut securely.
3.
Connect the other end of the grounding lug wire to a grounding point at your 
site.
To connect DC power feeds to the terminal blocks:
1.
Loosen the retaining screws on each terminal block.
2.
Insert the 0V DC (positive voltage) return wire into the center COM connector 
and the -48V DC power feed wire into either the left or right connector.
3.
Fasten the screws over the connectors.
4.
Turn the power switches on.
Warning: 
You must shut off the electric current to the DC feed wires before connecting the 
wires to the power supplies. Also, make sure that the power switch is in the off position.
Note: 
If there are multiple power supplies in the NetScreen-5000 Series system 
and any of them are off, then the Alarm LED on the Management Module glows 
red. This alarm indicates that maximum system stability requires all installed 
power supplies to be operational.
Thumbscrew
Power 
LED
DC Power
Terminal Block
Power Switch
Grounding
Screw
-48V
-48V
COM