Jotul GF 600 DV User Manual

Page of 28
7
ALCOVE:
MAXIMUM ALCOVE DEPTH:    24”   (61 cm)
MINIMUM ALCOVE WIDTH:    44”   (112 cm)
MINIMUM CEILING HEIGHT:   64”  (163 mm)
Stove and Vent Clearance
Requirements
Minimum Clearances from the Stove to
Combustibles: 
See Figs. 2-4.
Rear:
3”  (75 mm)
Ceiling:
33”  (840 mm)
Corner:
3”  (75 mm)
Right Side: 4”  (100 mm)
Left Side: 10” (254 mm)
 - for access to Lighting Instruction
plate
Minimum Clearances from the Vent Pipe
to Combustibles:
Horizontal Run:
Off the top of the pipe -
2”(50mm)
Off the sides and bottom -
1”(25mm)
Vertical Run:
All sides
1”(25mm)
* Allow 10” on left side of the appliance for
complete access to the lighting instructions
and control valve.
 REAR CLEARANCE  = 3” (75 mm)
Left Side*
Right Side
10”
(25.5 cm)
4”
(10 cm)
Figure 3.  Parallel Installation Clearances
3” (7.5 cm)
3 ”
(7.5 cm)
 3”
7.5 cm
Figure 4. Corner Installation Clearance.
24” or greater depth of ceiling
10” or less in depth
33”
84 cm
29”
74 cm
Figure 2. Mantel and Trim Clearances.