Multi-link Multi-Link Acp-300 ACP-300 User Manual

Page of 6
When programming this register, you must enter all Flag (Bit) values. The 
flags are preset to the following: Flag 1 (Bit 3) Device 4 Barge-in Mask 0 (off) 
Flag 2 (Bit 2) Device 3 Barge-in Mask 0 (off) 
Flag 3 (Bit 1) Device 2 Barge-in Mask 0 (off) 
Flag 4 (Bit 0) Device 1 Barge-in Mask 0 (off) 
 
Register 8 must also be set to a positive number to activate barge-in. 
 
REGISTER 08 - Barge-In Time 
This register contains the amount of time that a telephone receiver must be held 
off-hook to "barge-in" on a call. The range of this register is 0 (off) to 15 with a 2 
second multiplier for each digit. Factory preset to 0 (off). 
 
REGISTER 09 - Security Programming Time Window 
This register contains the number of minutes that the ACP will accept the 
programming code once power has been applied to the unit. The range of this 
register is 0 to 15. 
 
Factory preset to 0 (allows programming at all times). 
 
REGISTER 10 - Seizure Time 
This register contains the maximum number of seconds the ACP will hold the 
phone line, during a multiple polling sequence after a device has been 
disconnected. This register ranges from 10 to 99. Factory preset to 25 (no ring 
back is provided to caller during this time). 
 
(Note: ACP-9 utilizes Registers 11-15 plus 26-29. ACP-5 uses Registers 11-
15, and ACP-3 utilizes Registers only 11-13 for Device Codes. 
 
REGISTER 11 - Security Access Code for Device Port 1 
Contains the security access code for device port 1. This register holds up to 7 
digits ranging from 0 to 9, * and #. Factory preset to 11. 
 
REGISTER 12 - Security Access Code for Device Port 2 
Contains the security access code for device port 2. This register holds up to 7 
digits ranging from 0 to 9, * and #. Factory preset to 22. 
 
REGISTER 13 - Security Access Code for Device Port 3 
Contains the security access code for device port 3. This register holds up to 
digits ranging from 0 to 9 ' and #. Factory preset to 33 
 
REGISTER 14 - Security Access Code for Device Port 4 
Contains the security access code for device port 4. This register holds up to 7 
digits ranging from 0 to 9, " and #. Factory preset to 44.