CRS-300 1:10 Redundancy Switch 
Revision 16 
Cables and Connections 
MN/CRS300.IOM 
 4–24
 
4.5.3 
Control and Data Connections – CRS-300 to Modem 
 shows what TMI and applicable data and control cables are needed for each of the 
various data types. 
Table 4-1. CDM-625 Cable Usage (RMI/TMI) 
CDM-625 Cable Usage 
(See Appendix A. CABLE DRAWINGS for cable details) 
Driving Traffic Data Type 
CRS-310 RMI / Cable(s) 
TMI / Cable(s) 
G.703 
(Sect. 4.5.3.2) 
Bal/Unbal 
Control: CA/WR0066 
Data: CA-0000072 
CRS-330/340 
Control: CA/WR0066 
Data: CA-0000072 
Balanced 
Control: CA/WR0066 
Data: CA-0000072 
CRS-325 
Control: CA/WR0066 
Data: CA-0000072 
Unbalanced 
Control: CA/WR0066 
Data: PL/0813-8 (2X) 
Control: CA-0000069 
Data: PL/0813-8 (2X) 
ASI (Sect. 4.5.3.3) 
Control: CA/WR0066 
Data: PL/0813-8 (2X) 
CRS-325 
Control: CA-0000069 
Data: PL/0813-8 (2X) 
EIA-422 (Sect. 4.5.3.4) 
Control/Data: CA/WR0066 
CRS-316 
Control: CA-0000069 
Data: CA/WR0066 
CRS-340 
Control: CA/WR0066 
Data:  
HSSI (Sect. 4.5.3.5) 
Control/Data: CA/WR0066 
CRS-336 
Control: CA-0000069 
Data: CA/WR9189-6 with 
CIC-60 Adapter Module 
LVDS (Sect. 4.5.3.6) 
Control/Data: CA/WR0066 CRS-340 
Control/Data: 
CA/WR0066 
Ethernet 
(Sect. 4.5.3.8) 
Wired-thru 
(No Sub-Mux) 
(Sect. 4.5.3.8.1) 
Control: CA/WR0066 
Data: CA-0000121 
CRS-316 or 
CRS-336 
Control: CA-0000069 
Data: PP/CAT5FF7FTGY 
Wired-around 
(Sub-Mux) 
(Sect. 4.5.3.8.2) 
Control: CA/WR0066 
Data (by User): CAT5 to 
10/100/1000 Switch 
N/A N/A 
4.5.3.1  Required Control Cabling (Regardless of Driving Traffic Data Type) 
For RMI connections: 
The Control/Data Cable CA/WR0066 (DB-25F to DB-25M, 6’) provides 
the serial communication path between the Redundant CDM-625 and the CRS-300 (via the 
CRS-310 RMI) for all driving traffic data types, and is therefore always required.  
For all driving traffic data types
, refer to Figure 4-10 through Figure 4-12 to connect and 
secure the CA/WR0066 cable between the Redundant CDM-625 and the CRS-310 RMI on the 
CRS-300 as follows: 
•  DB-25F connector labeled “Data Interface” on Redundant CDM-625, to 
•  DB-25M connector labeled “P1” on the CRS-310 RMI. 
For TMI connections: 
Depending on the driving data traffic type, in addition to its use as a 
control cable between the Redundant CDM-625 and the CRS-310 RMI, the CA/WR0066 cable is 
used as a control cable between the Traffic CDM-625(s) and the CRS-330 or CRS-340 TMI; as a 
data cable with the CRS-316 TMI; and as a combination control/data cable when used with the 
CRS-340 TMI.