Mitsubishi Electronics Mitsubishi Digital Electronics Video Gaming Accessories FX3G User Manual

Page of 936
51
FX
3G
/FX
3U
/FX
3UC
 Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
1
In
trodu
ct
ion
2
O
ver
vi
ew
3
In
st
ru
ct
ion 
Li
st
4
D
evices 
in D
etail
5
Specifi
ed t
he
D
evice &
 
C
onst
ant
6
Bef
ore 
Pr
ogr
am
m
ing
7
B
asic 
In
st
ru
ct
ion
8
FNC0
0-F
NC0
9
Pr
ogr
am
 Flow
9
FN
C
10-FN
C
19
Mo
ve
 &
 Co
mp
are
10
FNC2
0-F
NC2
9
Ar
ith.
 &
 Logic 
O
per
ati
on
2.7.6
Special unit initial value setting [GX Developer Ver.8.23Z or later]
The initial values of the buffer memory (BFM) in special function blocks/units connected to an FX
3U
/FX
3UC
 PLC
(Ver.2.20 or later) can be set as a parameter in GX Developer (Ver.8.23Z or later).
When this parameter is used, it is not necessary to execute initial setting in a user program for special function blocks/
units requiring initial setting. The special unit initial value setting uses 4000 steps (8 blocks) in the memory capacity.
→ For the setting procedure, refer to Subsection 2.7.8.
2.7.7
Positioning setting [for TBL (FNC152) instruction] [GX Developer Ver.8.23Z or later]
In the positioning setting available in all FX
3G
 PLCs and FX
3U
/FX
3UC
 PLCs Ver. 2.20 or later, a table and constants for
added TBL (FNC152) instruction can be set. Make sure to set this parameter when using TBL (FNC152) instruction.
The positioning setting for TBL (FNC152) instruction uses 9000 steps (18 blocks) in the memory capacity.
→ For details on TBL (FNC152) instruction, refer to the Positioning Control Manual.
2.7.8
Built-in CC-Link/LT Setup (dedicated to FX
3UC
-32MT-LT-2)
The set item "Built-in CC-Link/LT Setup" is dedicated to the FX
3UC
-32MT-LT-2.
The CC-Link/LT setting (transmission speed, point mode and station information) is available in the parameter setting
using GX Developer Ver. 8.68W or later.  
The built-in CC-Link/LT setup uses 500 steps (1 block) in the memory capacity.
→ For the setting procedure, refer to the FX
3UC
 Hardware Manual or Subsection 2.7.9.
2.7.9
Parameter settings by GX Developer
This subsection explains the parameter setting procedures by GX Developer (Ver.8.72A).
→ For details on entry codes, refer to Subsection 2.7.5.
1
Opening the parameter setting screen
In the project tree area provided on the left side of the screen, double-click [Parameter] 
→ [PLC parameter].
If the project tree is not displayed, select [View] 