Minicom Advanced Systems Network Hardware 5UM7017 User Manual

Page of 137
AccessIT 
132
 
22. Technical Specifications 
Operating systems 
Target Server 
DOS, Windows, Novell, Linux, SUN Solaris for PC   
 
Client Computer 
Windows 2000 and later with Internet Explorer 6 and later or Firefox 3 
and later 
Linux x86 and Firefox 3 and later
 
Authentication  
Local or Microsoft Active Directory   
Security 
SSL, high grade 256-bit AES encryption 
Maximum # of users 
20 
Maximum # of IP devices 
50 
Maximum # of targets 
250 (servers and network devices) 
Replication unit 
Yes 
Backup / Restore 
Yes 
Device configuration 
Automatic discovery of Minicom IP KVM devices 
Firmware upgrade 
Yes 
Protocols 
HTTPS, XML, SSH, Telnet, LDAP 
Form factor 
1U x 19” rack mountable 
Network connection 
RJ45 
Power supply 
115-230 VAC, 50-60Hz autosensing 
 
Environmental 
 
Temperature 
Operating 10° to 35°C (50° to 95°F) 
Storage –40° to 65°C (–40° to 149°F) 
Relative humidity  
Operating 20% to 80% (non-condensing) with a maximum humidity 
gradation of 10% per hour 
Storage 5% to 95% (non-condensing) 
Maximum vibration 
Operating 0.26 Grms at 5–350 Hz for 15 min 
Storage 1.54 Grms at 10–250 Hz for 15 min 
Maximum shock 
Operating One shock pulse in the positive z axis (one pulse on each 
side of the system) of 31 G for up to 2.6 ms 
Storage Six consecutively executed shock pulses in the positive and 
negative x, y, and z axes (one pulse on each side of the system) of 71 
G for up to 2 ms 
Altitude 
Operating –16 to 3,048 m (–50 to 10,000 ft) 
NOTE: For altitudes above 2,950 feet, the maximum operating 
temperature is derated 1°F/550 ft. 
Storage –16 to 10,600 m (–50 to 35,000 ft) 
Airborne contaminant 
level
 
Class G2 or lower as defined by ISA-S71.04-1985