Lux Products T10-1143SA Instruction Manual

Page of 4
2
Heating Systems
G
Y
W RH
B
O
RC
Tape Off *
  * If replacing a Honeywell TM-11,
     tape off wire “R”; connect wire “B”
     to terminal “RH.”
** If replacing a Honeywell thermostat
     with a clock wire “C,” tape off wire “C”
G
5
4
B
RC
V
R
*
H
W
F
RH
Tape Off **
C
Tape Off
TC
FAN RELAY
          COOLING COMPRESSOR
                   HEATING CONTROL
                             HEATING TRANSFORMER
                                        DAMPER OR CHANGEOVER VALVE
                                                
(POWERED IN HEAT)
                                                DAMPER OR CHANGEOVER VALVE
                                        
                   
(POWERED IN COOL)
                                                           COOL TRANSFORMER
Cooling Systems
G
Y
W RH
B
O
RC
Y
V
R
C
R
C
G
F
TC
Tape Off
FAN RELAY
          COOLING COMPRESSOR
                   HEATING CONTROL
                             HEATING TRANSFORMER
                                        DAMPER OR CHANGEOVER VALVE
                                                
(POWERED IN HEAT)
                                                DAMPER OR CHANGEOVER VALVE
                                        
                   
(POWERED IN COOL)
                                                           COOL TRANSFORMER
* If both Y and C wire are 
present, tape  off  “C” wire.
*
Heating/Cooling Systems
4- or 5-Wire with One Transformer
G
Y
W RH
B
O
RC
C
Y
G
F
W
V
R
RC
B
O
(Optional)
(Optional)
Tape Off
TC
FAN RELAY
          COOLING COMPRESSOR
                   HEATING CONTROL
                             HEATING TRANSFORMER
                                        DAMPER OR CHANGEOVER VALVE
                                                
(POWERED IN HEAT)
                                                DAMPER OR CHANGEOVER VALVE
                                        
                   
(POWERED IN COOL)
                                                           COOL TRANSFORMER
* If both Y and C wire are 
present, tape off “C” wire.
*
FAN RELAY
          COOLING COMPRESSOR
                   HEATING CONTROL
                             HEATING TRANSFORMER
                                        DAMPER OR CHANGEOVER VALVE
                                                
(POWERED IN HEAT)
                                                DAMPER OR CHANGEOVER VALVE
                                        
                   
(POWERED IN COOL)
                                                           COOL TRANSFORMER
Heating/Cooling Systems
5- or 6-Wire with Two Transformers
G
Y
W RH
B
O
RC
Y
C
G
F
W
4
A
RH
B
O
(Optional)
(Optional)
V
R
R
C
Tape Off
TC
*
* If both Y and C wire are 
present, tape off “C” wire.
WIRING DIAGRAMS