Screen reference 
998
Trunk Group 
17
Disconnect Supervision-Out
This field indicates whether the switch receives disconnect supervision for 
outgoing calls over this trunk group. It appears when the Direction field is either 
outgoing
 or 
two-way
. (If the Direction field is 
incoming
, the switch internally 
sets this field to 
n
.)
The entry in this field is crucial if you allow trunk-to-trunk transfers. (To allow 
trunk-to-trunk transfers involving trunks in this group, this field must be 
y
 and the 
Trunk-to-Trunk Transfer field on the Feature-Related System Parameters screen 
must be 
y
). If a user connects 2 trunks through conference or transfer, and neither 
far-end switch on the resulting connection provides disconnect supervision, the 
trunks involved will not be released because DEFINITY ECS can’t detect the end 
of the call. DEFINITY ECS will not allow trunk-to-trunk transfers unless it 
believes that at least one party on the call can provide disconnect supervision. 
Therefore, setting this field incorrectly may cause trunks to become unusable until 
the problem is detected and the trunks are reset.
Also, remember that DEFINITY ECS must receive answer supervision on 
outgoing analog CO, FX, WATS, Tie, Tandem, and Access trunks before it will 
recognize a disconnect signal. If this trunk group does not receive answer 
supervision from the far-end switch, and you enter y in this field, DEFINITY ECS 
will internally set the field to n. 
!
CAUTION:
Do not set this field to 
y
 unless you are certain that the far-end switch will 
provide answer supervision and disconnect supervision. Most public 
networks do not provide disconnect supervision over analog trunks. Check 
with your network services provider. 
Valid entries
Usage
y
Enter 
y
 if (a) the far-end switch sends a release signal when the 
called party releases a call an outgoing call, and (b) you want to 
make the far-end switch responsible for releasing the trunk. 
This entry allows trunk-to-trunk transfers involving trunks in 
this group.
The Answer Supervision Timeout field must be 
0
 and the 
Receive Answer Supervision field must be 
y
 for the switch to 
recognize a 
y
 entry.
n
 Enter 
n
 if the far-end switch doesn’t provide a release signal, if 
your hardware can’t recognize a release signal, or if you prefer 
to use timers for disconnect supervision on outgoing calls. 
Entering 
n
 prevents trunk-to-trunk transfers involving trunks in 
this group.