Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
1002
Trunk Group 
17
Customer-Options screen. If the ATM field is set to 
y
 on the System-Parameters 
Customer-Option screen, this field accepts only 
internal
 or 
none
. If this field 
contains a value other than 
internal
 or 
none
 when ATM is 
y
none
 appears.
Long Holding Time (hours)
This field appears only when the ACA Assignment field is 
y
.
I
nternal Alert
Maintenance Tests
Short Holding Time (seconds)
This field appears when the ACA Assignment field is 
y
.
Valid entries
Usage
internal
Enter 
internal
 if the data can be sent to the Basic Call 
Management System (BCMS), the VuStats data display, or 
both.
external
Enter 
external
 to send the data to the CMS.
both
Enter 
both
 to collect data internally and to send it to the CMS.
none 
Enter 
none
 if trunk group measurement reports are not 
required.
Valid entries
Usage
0
 to 
10
Enter the length of time (in hours) that the system will consider 
as being a long holding time. If you enter 
0
, the system will not 
consider long holding calls.
Valid entries
Usage
y/n 
Enter 
y
 if internal ringing and coverage will be used for 
incoming calls.
Valid entries
Usage
y/n 
Enter 
y
 if hourly maintenance tests will be made on this trunk 
group. Your entry is not saved when the screen is submitted 
unless one or more trunk members are administered.
Valid entries
Usage
0
 to 
160
Enter the length of time (in seconds) that the system considers 
as being a short holding time. If 
0
 is entered, the system will 
not consider short holding calls.