Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
1011
Trunk Group 
17
Incoming Disconnect (msec)
The field appears only for an incoming or two-way trunk group when the Trunk 
Signaling Type field is either blank or 
cont
.
Outgoing Disconnect (msec)
Cama Outgoing Dial Guard (msec)
This field appears when Group Type is 
cama
 (the trunk group type used for 
emergency 911 service).
Incoming Dial Guard (msec
)
NOTE:
This timer is never sent to TN429 ports.
Valid entries
Usage
50
 to 
2550
 in 
increments of 
10
Enter the minimum valid duration of a disconnect signal for an 
incoming call. The switch will not recognize shorter disconnect 
signals. This field cannot be blank. For Brazil pulsed E&M 
signaling, use 
600
.
Valid entries
Usage
50
 to 
2550
 in 
increments of 
10
Enter the minimum valid duration of a disconnect signal for an 
outgoing call. The switch will not recognize shorter disconnect 
signals. This field cannot be blank. This timer begins timing 
when a disconnect signal is detected on an outgoing call and 
resets when the signal is no longer detected. If the timer 
expires, the trunk drops. For Brazil pulsed E&M signaling, use 
600
.
Valid entries
Usage
25
 to 
6375
 in 
increments of 
25
Enter the minimum interval between the receiving switch’s 
seizure acknowledgment and the outpulsing of digits by this 
switch.
Valid entries
Usage
10
 to 
2550
 in 
increments of 
10
Enter the minimum acceptable interval between the detection 
of an incoming seizure and the acceptance of the first digit. The 