Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
1019
Trunk Group 
17
Pause (msec)
THis field is administrable only if the Trunk Signaling Type field is blank. All 
CO, DIOD, and tie circuit packs that accept administrable timers accept this timer. 
However, this timer is sent only to the following circuit packs: TN464B (or later), 
TN767, TN436B, TN459B, TN2146, TN2199, and TN2242, and TN429 and 
TN2184 ports in a DID trunk group.
PPS
NOTE:
The TN439, TN458, TN497, TN747Bv12 (or later), and TN767 circuit 
packs only send rotary pulses at 10 pps.
Make (msec)
Valid entries
Usage
20
 to 
2550
 in 
increments of 
10
Enter the minimum acceptable interval (pause) between DTMF 
tones sent from a hybrid phone.
Valid entries
Usage
10
 
Enter the rate (pulses per second) at which outgoing rotary 
pulses are sent over this trunk group.
20
Valid entries
Usage
Enter the duration of the make interval (the pause between pulses) while the 
system is outpulsing digits using dial pulse signaling. The field cannot be blank.
20
 to 
80
 in 
increments of 5
If the PPS field is 
10
, the sum of the Make (msec) and Break 
(msec) fields must equal 100.
10
 to 
40
 in 
increments of 5
If the PPS field is 
20
, the sum of the Make (msec) and Break 
(msec) fields must equal 50.