Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Handling incoming calls 
171
Assigning a terminating extension group 
7
2. In the Group Extension field, type 
6725
.
This is the extension for the advertising group.
3. In the Group Name, type 
advertising
.
This is the name of the group.
4. In the Coverage Path field, type 
5
.
This is the number of the call coverage path for this group.
5. In the COR field, leave the default as 
1
.
6. In the TN field, leave the default as 
1
.
7. In the ISDN Call Display field, type 
mbr-name
.
This specifies that the member name (member of the TEG where the call 
terminated) is sent to the originating user.
8. In the Ext field, in the 1st place, type 
5101
.
9. In the 4th place, type 
5102
.
10. Press 
ENTER
 to save your changes.
11. Type 
change station 6725
 and press 
RETURN
.
The 
Station
 screen for extension 6725 appears.
 
                       TERMINATING EXTENSION GROUP
    Group Number: 1                             Group Extension: 6725
      Group Name: advertising  
Coverage Path: 5
   Security Code:                                           COR: 1
                                                             TN: 1
ISDN Caller Disp: mbr-name
 LWC Reception: none
      AUDIX Name:                         Messaging Server Name:
GROUP MEMBER ASSIGNMENTS
    Ext     Name                            Ext     Name
 1: 5101
 27 character name sta 51001  3:
 2:                                      4: 5102
 27 character name sta 51002