Managing multimedia calling 
236
Multimedia Call Handling 
9
ESM Installation
Figure Notes
Figure 11.
Typical Multimedia Call handling ESM Connections
Use the following procedure and 
Figure 11
 to connect to the ESM equipment:
1. Install the TN2207 primary rate interface (PRI) circuit pack and the TN787 
multimedia interface (MMI) circuit pack in the DEFINITY System port 
carrier. 
NOTE:
These two circuit packs should be co-located in the cabinet since they 
must be connected by a Y-cable on the back plane of the DEFINITY 
ECS.
2. Record the circuit pack locations.
3. Connect the ESM Y-cable as shown.
4. Administer the DS1 form and the signaling-group form for the ESM (see 
‘‘ESM T.120 Server Administration’’ on page 247
).
5. Configure the ESM adjunct.
1. Port B Y-cable connector to a TN787 
multimedia interface (MMI) circuit pack
2. Port A Y-cable connector to a TN2207 
PRI circuit pack 
3. 25-pair Y-cable
4. 356A adapter
5. D8W cord connected to 356A 
adapter S/B port 8
6. Expansion service module 
(ESM)
7. Port B on compatible primary 
rate interface (PRI) card
cydf012 RPY 100697
1
2
4
5
3
6