Enhancing system security 
311
System security checklist 
11
5. If you use vectors:
a. Assign all Vector Directory Numbers (VDN) a unique COR. Refer 
to DEFINITY ECS Guide to ACD Call Centers for more 
information.
NOTE:
The COR associated with the VDN dictates the calling privileges of 
the VDN/vector. High susceptibility to toll fraud exists on vectors 
that have “collect digits” steps. When a vector collects digits, it 
processes those digits back to the switch and if the COR of the VDN 
allows it to complete the call off-net, it will do so. For example, the 
announcement “If you know your party’s 4-digit extension number, 
enter it now” results in 4 digits being collected in step 6. If you input 
“90##” or “900#”, the 4 digits are analyzed and if “9” points towards 
ARS and “0” or “00” is assigned in the ARS Analysis Tables and the 
VDN COR allows it, the call routes out of the switch to an outside 
local exchange or long distance operator. The operator then connects 
the call to the requested number.
b. If vectors associated with the VDN do not require routing the call 
off-net or via AAR, assign a unique COR where the FRL is 
0
, the 
Calling Party Restriction field is 
outward
, the Calling Permissions 
field is 
n
 on all unique Trunk Group COR.
c. If the vector has a “route-to” step that routes the call to a remote 
switch via AAR, assign a unique COR with a unique ARS/AAR 
Partition Group, the lowest FRL to complete an AAR call, and 
n
 on 
all unique COR assigned to your public network trunking facilities 
on the Calling Permissions. Assign the appropriate AAR route 
patterns on the AAR Partition Group using the 
change aar analysis 
partition x 2
 command.
Tip:
You can use the 
display aar analysis print
 command to print 
a copy of your Automatic Alternate Routing (AAR) setup 
before making any changes. You can use the printout to correct 
any mistakes.
d. If the vector has a “route-to” step that routes the call to off-net, 
assign a unique COR with a unique ARS/AAR Partition Group, the 
lowest FRL to complete an ARS call, and 
n
 on all unique COR 
assigned to your public network trunking facilities on the Calling 
Permissions. Assign the appropriate complete dial string in the 
“route-to” step of the vector the unique ARS Partition Group using 
the 
change ars analysis partition x 2
 command.