Screen reference 
633
Feature-Related System Parameters 
17
Self Station Display Enabled
Use this field to control the use of the 
INSPECT
 button for digital display phones.
Self Station Display allows a user to display the primary extension associated with 
a digital display phone. There are two methods: (1) enter a feature access code 
(FAC), and (2) use the 
INSPECT
 button. In either case, the display shows the 
primary extension associated with the phone where the FAC or 
NORMAL
 or 
EXIT
 
button is entered. In the case of the FAC, the display continues until a 
display-altering event occurs (for instance, going on-hook or receiving an 
incoming call). In the case of the 
INSPECT
 button, the display continues until the 
user presses the 
NORMAL
 or 
EXIT
 button or until a display-altering event occurs.
Trunk-to-Trunk Transfer
Regulations in some countries control the settings for this field. See your Lucent 
Technologies representative for assistance.
Automatic Callback — No Answer Timeout 
Interval (rings)
Valid entries
Usage
y
The primary extension does display when the 
INSPECT
 button is 
pressed.
n
 
The extension does not display when the 
INSPECT
 button is 
pressed.
Valid entries
Usage
all
Enter 
all
 to enable all trunk-to-trunk transfers. This allows 
telephone users to set up trunk-to-trunk transfer, go on-hook 
without disconnecting the call, and forward the call to a remote 
location.
restricted
Enter 
restricted
 (restricted public) to restrict all public trunks 
(CO, WATS, FX, CPE, DID, and DIOD).
none
 Enter 
none
 to restrict all trunks (except CAS and DCS) from 
being transferred.
Valid entries
Usage
2–9
Enter the number of times the callback call rings at the calling 
station before the callback call is canceled.