Lucent Technologies Definity Enterprise Communication Server 8.2 User Manual

Page of 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
744
ISDN trunk group 
17
Processor Interface Data Module — Use this screen only for a TN765. 
Assign up to 8 interface links using 8 Processor Interface Data Module 
screens for multi-carrier cabinet systems, and up to 4 links for 
single-carrier cabinet systems. One Processor Interface Data Module 
screen must be completed for each interface link to be assigned.
Communication Interface Links — Use this screen only for a TN765. 
Assign link numbers 01 to 08 for a multi-carrier cabinet system or links 01 
to 04 for a single-carrier cabinet system as required. When first 
administering this screen in DEFINITY ECS for ISDN, do not administer 
the Enable field.
Communication Processor Channel Assignment — Use this screen only for 
a TN765. Enter assigned link numbers and assign associated channel 
numbers to each link. Complete all fields of the screen as required. When 
first administering this screen in DEFINITY ECS for ISDN, you need to:
— First, administer the Interface Links screen, except the Enable field.
— Second, administer the ISDN fields on the Processor Channel 
screen.
— Last, go back to the Interface Links screen and administer the 
Enable field.
ISDN Numbering - Public/Unknown — Complete all fields. This screen 
supports the ISDN Call Identification Display.
ISDN Numbering - Private — Complete all fields. This screen supports the 
ISDN Call Identification Display.
Routing Pattern — Complete all fields including the Supplemental ISDN 
Routing Information fields as required.
Hunt Group — Complete the ISDN Caller Display field by entering either 
grp-name
 or 
mbr-name
 to specify whether the hunt group name or 
member name, respectively, is sent to the originating user (supports the 
ISDN Call Identification Display feature).
Terminating Extension Group — Complete the ISDN Caller Display field 
by entering either 
grp-name
 or 
mbr-name
 to specify whether the group 
name or member name, respectively, is sent to the originating user 
(supports the ISDN Call Identification Display feature).
Synchronization Plan — Assigns primary and secondary external 
synchronization sources for the ISDN-BRI Trunk or DS1 circuit pack. 
Complete all screen fields as required.