825
Multifrequency-Signaling-Related System Parameters 
17
A
NI for PBX
This field appears only when Outgoing Call Type is 
group-ii-mfc
 or 
mfe
.
MFE Type
This field only appears when Incoming Call Type is 
mfe
 and the Outgoing Call 
Type is 
mfe
 or 
none.
Maintenance Call Type
Next ANI Digit
This field appears when Outgoing Call Type is 
group-ii-mfc
.
Valid entries Usage
2
 to 
15 
Enter the PBX identification number that is sent to the CO when 
ANI is requested (by the CO) on a particular call but is not 
available, such as on tandem tie trunk calls. 
blank
Use for tandeming. If this field is blank, you must enter a value in 
the ANI-Not-Available field.
Valid entries
Usage
2/5
 
Determines which public signaling the switch will use.
2/6
Valid entries
Usage
1
The Belgium maintenance sequence is indicated when the CO 
sends an MFC maintenance tone.
2
The Saudi Arabian sequence is indicated when the CO sends an 
MFC maintenance tone.
Valid entries
Usage
next-digit
next_ani_digit
send-ani
Enter a value to determine whether the Next ANI Digit signal 
will be the same as the “send-ani” signal or the “next-digit” 
signal or another signal defined as “next_ani_digit.”