Electrical Specifications
Figure 6.25 Normal/Fast Memory (
=
128 Kbytes) Single Byte Access Read Cycle
Table 6.31
Normal/Fast Memory (
=
128 Kbytes) Single Byte Access Read Cycle
Symbol
Parameter
Min
Max
Unit
t
11
Address setup to MAS/ HIGH
25
ns
t
12
Address hold from MAS/ HIGH
15
ns
t
13
MAS/ pulse width
25
ns
t
14
MCE/ LOW to data clocked in
150
ns
t
15
Address valid to data clocked in
205
ns
t
16
MOE/ LOW to data clocked in
100
ns
t
17
Data hold from address, MOE/, MCE/ change
0
ns
t
18
Address out from MOE/, MCE/ HIGH
50
ns
t
19
Data setup to CLK HIGH
5
ns
CLK
MAD
(Addr driven by LSI53C875A;
Data driven by memory)
MAS1/
(Driven by LSI53C875A)
MAS0/
(Driven by LSI53C875A)
MCE/
(Driven by LSI53C875A)
MOE/
(Driven by LSI53C875A)
MWE/
(Driven by LSI53C875A)
t
11
t
12
t
13
t
15
t
14
t
16
t
18
t
17
t
19
Higher
Address
1.
2.
3.
1. Middle Address
2. Lower Address
3. Valid Read Data