LSI 53C810A User Manual

Page of 238
DC Characteristics
7-5
Table 7.9
Output Signal—SERR/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OL
Output low current
16
mA
0.4 V
I
OZ
3-state leakage
10
10
µ
A
Table 7.10
Bidirectional Signals—AD[31:0], C_BE/[3:0], FRAME/, IRDY/, TRDY/,
DEVSEL/, STOP/, PERR/, PAR/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
IH
Input high voltage
2.0
V
DD
+0.5
V
V
IL
Input low voltage
V
SS
0.5
0.8
V
V
OH
Output high voltage
2.4
V
DD
V
16 mA
V
OL
Output low voltage
V
SS
0.4
V
16 mA
I
OH
Output high current
8
mA
V
DD
0.5
Note: All the signals in this table have 100
µ
A pull-ups that are enabled when TESTIN is low.