Lightolier LUPS Series Leaflet

Page of 2
LUPS Series Uninterruptible Power Supplies
LUPS
Page 1 of 2
550 - 1,500 VA Sine Wave UPS System
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier 
a Genlyte Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC (Lightolier Division) • C0406
Overall Characteristics
• 83% throughput efficiency
• Single conversion UPS, No transfer time
• Operating temperature range of 32°F (0°C) to 104°F (40°C); 65°F (19°C) to
85°F (29°C) maximum for batteries
• Standard 90 minutes of operating time
• Full-time, isolating transformer
• Variable Range Regulator allows wider range of acceptable input voltage
variation
• ANSI/IEEE C62.41 category A & B surge voltage withstand capability
Housing
• Free standing, NEMA 1 enclosure with locking doors
• Acid resistant powder coat finish
• Multiple conduit entries
Standard Metering/Controls
• AC input and output voltage
• AC input breaker
• AC output breaker
• Battery disconnect device
• Automatic battery monitor with alarm
• LED indicating lamps for system on, system on battery, low battery warning 
Battery
Maintenance free, sealed lead calcium battery has an estimated service life of
10 years, and operating temperature range of 65°F (19°C) to 85°F (30°C)*.
* Increases or decreases in temperature will affect battery performance. Optimum battery performance
realized at 77°F (25°C).  Batteries are rated at 100% capacity at 77°F (25°C).
Electronics
Input
• Input power factor self-correcting to > 0.95
• Frequency 60.0 ±2.5 Hz
• Input voltage tolerance +10% to -15%
• Input harmonics < 8% THD
Output
• Solid-state PWM inverter with sine wave output
• Output voltage regulation ±3% of nominal at full load
• Output frequency 60 Hz ±0.2%
• Load power factor capability is 0.6 lagging to unity
• Overload rating: 125% for 10 minutes
• Efficiency: 82% to 86%
Charger
• Low voltage disconnect (LVD)
• 3 amp, 2-stage
• Recharge time: UL 924 compliant
Options
FSU = Start-up Service
EXT = Extended Warranty (with FSU only)
How to Specify:
31.0”
78.7 cm
39.0”
99.1 cm
550 VA
1000 VA
1500 VA
Cabinet &
223 lbs.
223 lbs.
262 lbs.
Electronics
(101 kg)
(101 kg)
(119 kg)
Sealed Lead
Calcium Battery
10 Minute
44 lbs.
59 lbs.
88 lbs.
Backup
(19.9 kg)
(26.8 kg)
(39.9  kg)
20 Minute
54 lbs.
88 lbs.
108 lbs.
Backup 
(24.5 kg)
(39.9 kg)
(49.0  kg)
90 Minute
121 lbs.
203 lbs.
288 lbs.
Backup
(55 kg)
(92 kg)
(131 kg)
LUPS
Series
VA Rating
Voltage
Output Circuit
Configuration
Breakers
LUPS = LUPS Uninterruptible
550 = 550 VA
Input Output                            OCB1 = (550 VA)
Power Supply for
1000 = 1,000 VA
A = 120 120                                 OCB3 = (1000, 1500 VA)
Emergency Lighting
1500 = 1,500 VA   
B = 277
277
Applications
LUPSX = 10 Minute Backup
LUPSY = 20 Minute Backup
16.6”
42.2 cm
Operates incandescent, electronic ballast loads and HID lighting loads as well as critical loads requiring conditioned emergency power.