LaCie FIREWIRE 800/400 User Manual

Page of 59
LaCie Biggest Quadra
User Manual
page 
Setting Up the Biggest Quadra
4.2. Creating an Array
To initialize the disks in your array:
Make sure the Biggest Quadra is turned off and the 
power cable is not connected.
Ensure  that  the  RAID  level  is  correctly  set  and 
configured. Refer to section 
4.1. Setting the RAID 
Level
.
Ensure that each of the individual drive trays is not 
locked and then pull each drive tray handle to release 
the latch. Slide each of the drive trays out from the 
LaCie Biggest Quadra slightly (Fig. 4.2.A).
Connect  the  power  cable  to  the  LaCie  Biggest 
Quadra and a grounded electrical outlet. See 
A
 in-
Fig. 4.2.B.
Turn on the LaCie Biggest Quadra by moving the 
power  switch  to  the  “on”  position.  See 
B
  in  Fig. 
4.2.B.
Slide each of the drive trays back into the LaCie Big-
gest Quadra, and push the drive tray handles flat to 
lock the drive trays into place (Fig. 4.2.C).
Once  all  of  the  drive  trays  have  been  closed  and 
locked, the LaCie Biggest Quadra will check the status 
of the four installed disks. If all four of the disks have 
not been initialized before (which will be the case for 
the first connection of the LaCie Biggest Quadra), the 
RAID level initialization will begin automatically.
1.
2.
3.
4.
5.
6.
Fig. 4.2.A
USB
eSATA
0
5
0-1
5-S
Fig. 4.2.B
Fig. 4.2.C
on
off
4.2.1. Initializing the Disks
(continued on next page)