IBM Partner Pavilion DS4100 User Manual

Page of 180
DS4100
 
specifications
 
lists
 
the
 
physical
 
specifications
 
for
 
the
 
DS4100.
 
 
Table
 
9.
 
IBM
 
TotalStorage
 
DS4100
 
specifications
 
Size
 
v
   
Width:
 
48.18
 
cm
 
(18.97
 
in.)
 
v
   
Height:
 
13.23
 
cm
 
(5.21
 
in.)
 
v
   
Depth:
 
59.74
 
cm
 
(23.52
 
in.)
Weight
 
v
   
Drive-ready
 
weight
 
(without
 
disk
 
drive
 
modules
 
installed):
 
   
Model
 
100:
 
26.64
 
kg
 
(58.9
 
lb)
 
   
Model
 
1Sx:
 
23.44
 
kg
 
(51.9
 
lb)
v
   
Fully
 
configured
 
weight
 
(with
 
14
 
disk
 
drives
 
installed):
 
   
Model
 
100:
 
40.36
 
kg
 
(89
 
lb)
 
   
Model
 
1Sx:
 
37.16
 
kg
 
(82
 
lb)
Environment
 
v
   
Air
 
temperature
 
   
Operating:
 
-
   
Altitude:
 
0
 
-
 
914
 
m
 
(3000
 
ft):
 
10°
 
-
 
35°
 
C
 
(50°
 
-
 
95°
 
F)
 
-
   
Altitude:
 
914
 
m
 
-
 
2133
 
m
 
(3000
 
-
 
7000
 
ft):
 
10°
 
-
 
32°
 
C
 
(50°
 
-
 
90°
 
F)
Important:
 
The
 
recommended
 
operating
 
environment
 
air
 
temperature
 
is
 
22°
 
C
 
(72°
 
F)
 
or
 
lower.
 
   
Storage:
 
-
   
Altitude:
 
0
 
-
 
914
 
m
 
(3000
 
ft):
 
 
-
 
60°
 
C
 
(33°
 
-
 
140°
 
F)
 
-
   
Altitude:
 
914
 
m
 
-
 
2133
 
m
 
(3000
 
-
 
7000
 
ft):
 
 
-
 
57°
 
C
 
(33°
 
-
 
135°
 
F)
v
   
Humidity
 
   
8%
 
-
 
80%
 
   
Noncondensing
 
Heat
 
dissipation
 
v
   
Fully
 
configured
 
storage
 
server
 
(14
 
1.5
 
Gbps
 
SATA
 
hard
 
disk
 
drives)
 
   
1235
 
BTU
 
per
 
hour
Acoustical
 
noise
 
emission
 
values
 
For
 
open
 
bay
 
(0
 
drives
 
installed)
 
and
 
typical
 
system
 
configurations
 
(eight
 
hard
 
disk
 
drives
 
installed):
 
v
   
Sound
 
power
 
(idling):
 
   
5.9
 
bel
 
(open
 
bay)
 
   
6.1
 
bel
 
(typical)
v
   
Sound
 
power
 
(operating):
 
   
5.9
 
bel
 
(open
 
bay)
 
   
6.2
 
bel
 
(typical)
v
   
Sound
 
pressure
 
(idling):
 
   
44
 
dBA
 
(open
 
bay)
 
   
46
 
dBA
 
(typical)
v
   
Sound
 
pressure
 
(operating):
 
   
44
 
dBA
 
(open
 
bay)
 
   
47
 
dBA
 
(typical)
These
 
levels
 
are
 
measured
 
in
 
controlled
 
acoustical
 
environments
 
according
 
to
 
ISO
 
7779
 
and
 
are
 
reported
 
in
 
accordance
 
with
 
ISO
 
9296.
 
The
 
declared
 
sound
 
power
 
levels
 
indicate
 
an
 
upper
 
limit,
 
below
 
which
 
a
 
large
 
portion
 
of
 
machines
 
operate.
 
Sound
 
pressure
 
levels
 
in
 
your
 
location
 
might
 
exceed
 
the
 
average
 
1-meter
 
values
 
stated
 
because
 
of
 
room
 
reflections
 
and
 
other
 
nearby
 
noise.
  
Notes:
  
1.
   
The
 
nonoperating
 
environment
 
must
 
not
 
exceed
 
the
 
operating
 
environment
 
limits
 
for
 
longer
 
than
 
60
 
days.
 
2.
   
The
 
storage
 
environment
 
must
 
not
 
exceed
 
the
 
operating
 
environment
 
limits
 
for
 
longer
 
than
 
1
 
year.
 
3.
   
Substantial
 
deviations
 
from
 
the
 
suggested
 
operating
 
range,
 
in
 
either
 
direction,
 
if
 
sustained
 
for
 
extended
 
periods
 
of
 
time,
 
will
 
expose
 
the
 
unit
 
to
 
greater
 
risk
 
of
 
failure
 
from
 
external
 
causes.
 
The
 
AC
 
power
 
sources
 
must
 
provide
 
the
 
correct
 
voltage,
 
current,
 
and
 
frequency
 
specified
 
on
 
the
 
storage
 
server.
 
The
 
storage
 
server
 
can
 
run
 
without
 
interruption
 
within
 
the
 
limits
 
shown
 
in
 
 
 
 
14
 
IBM
 
TotalStorage
 
DS4100
 
Storage
 
Server:
 
Installation,
 
User’s,
 
and
 
Maintenance
 
Guide