Appendix C • Installing the DW4020 Manually
108
1031484-0001 Revision 2
Verifying software 
download
If the Gateway is configured correctly for outroute reception and 
SQF is greater than 30, it will acquire the outroute. As soon as the 
Gateway acquires the outroute, it begins to look for the Hub 
Server in the data stream to perform software download.
1. To monitor software download (SDL) progress, enter at the 
Main Menu
 prompt to select 
Software Download Monitor
.
2. The following message is displayed at the bottom of the 
screen:
SDL Initialization complete. Awaiting first heartbeat msg.
This message is dynamically updated. It indicates that SDL 
has started and is waiting to connect with the hub server.
3. If SDL does not progress beyond this message, check the 
following:
• The SDL control channel’s multicast IP address
– Return to the 
Main Menu
.
– Enter 
b
 to view the current configuration
– Check that the 
SDL Control Channel Multicast Address 
is 
correct. If not, enter the correct address.
• The Ready lights to ensure they are on. See The DW4020 
4. When the Gateway receives a message from the Hub Server, 
the following message is displayed:
Received first heartbeat message.
5. If there is no progress beyond this message, check the return 
path. When operating normally, the following message is 
displayed:
Note:
It may be 20 minutes before the first heartbeat message is 
received.
Received File/Group message. Reconciling files...
MM loading...
IP loading...
...
All files downloaded. Notifying CFM.