Huawei ME99 Series Mini PCIe Module ME909 User Manual

Page of 58
 
HUAWEI ME909 Series Mini PCIe Module   
Hardware Guide   
Electrical and Reliability Features 
 
Issue 0.1 (2013-06-09) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
35 
 
5.3 Operating
 
and Storage Temperatures and Humidity 
‎Table 5-2 lists the operating and storage temperatures and humidity for the ME909 
module. 
Table 5-2  Operating and storage temperatures and humidity for the ME909 module   
Specification 
Min. 
Max. 
Unit 
Normal working temperatures
[1]
 
–20 
+60 
°C 
Ambient temperature for storage 
–40   
+85 
°C 
 
 
[1]: When the ME909 module works at this temperature, all its RF indexes comply with the 
3GPP TS 45.005 and 3GPP TS 34.121-1 specifications. 
 
5.4 Electrical Features of USIM   
Table 5-3  Electrical features of Digital Pins in the I/O supply domain of the USIM 
Interface 
Parameter  Description 
Minimum Value  Maximum Value 
Unit 
V
IH
 
Logic high-level 
input voltage 
0.65 x V
DD_PX
 
V
DD_PX
 + 0.3 
V
IL
 
Logic low-level 
input voltage 
–0.3 
0.35 x V
DD_PX
 
V
OH
 
Logic high-level 
output voltage 
V
DD_PX
–0.45 
V
DD_PX
 
V
OL
 
Logic low-level 
output voltage 
0.45 
 
5.5 Electrical Features of Application Interfaces 
‎Table 5-4 lists electrical features (typical values). 
Table 5-4  Electrical features of application interfaces 
Parameter  Description 
Minimum Value  Maximum Value 
Unit 
V
IH
 
Logic high-level 
input voltage 
0.65 x V
DD_PX
 
V
DD_PX
 + 0.3