The following control actions are allowed on PESMs: 
 
• 
Turn Energy Saver On and Off 
• 
Turn Energy Saver On and Off for a specified time 
• 
Set heating setpoint 
• 
Set cooling setpoint 
 
You can turn the energy saver on, off, use a timed on/off, and change the Heat and Cool temperatures from the console or by 
telephone.  Commands can also be programmed so that they occur by time schedule or by event, such as security mode change.  
For example, the system can be set up to turn the energy saver(s) On and make the Heat setback temperature 65 degrees and the 
Cool setback temperature 80 degrees when the alarm system is put in the Away mode.  Another program can turn the energy 
saver(s) off (to resume normal operation of the HVAC system) at 4:30 P.M. on weekdays to make the house comfortable before 
arriving home.  Different setback temperatures could be set for the Night mode.   
 
NOTE: To set up your thermostat for use with a PESM, set it in the appropriate mode and set the temperature to your preference.  
Your heating and cooling system will always be off if you set your thermostat to Off mode.  The PESM cannot turn it back on.  
The PESM cannot make your system cool below the thermostat's cool setting, or heat above the thermostat's heat setting. 
 
Control actions for temperature sensors: 
 
• 
Set low setpoint 
• 
Set high setpoint 
 
To enter the temperature menu, from the top-level display or from the main menu, press the 5 (TEMP) key on the console keypad.  
You will be prompted with the first named temperature zone (i.e. Upstairs).  The temperature zone can be specified by entering 
the temperature zone number followed by the ' # ' key, or by pressing the arrow keys to scroll through the list of temperature 
zones.  Press the ' # ' key when the desired temperature zone is shown.   
 
 
 
   TEMPERATURE 
ZONE:
 
   ENTER 
TEMPERATURE 
ZONE 
 
 
After the ' # ' key is pressed, a menu appropriate for the type of temperature zone is shown. 
 
For Programmable Energy Saver Modules: 
 
 
 
 
Upstairs  
 
 
 
 
 
0=OFF   1=ON    2=HEAT 
 
 
   Upstairs 
 
 
 
 
 
 
 
 
3=COOL  4=TIME  #=STAT 
 
 
For temperature sensors: 
 
 
 
 
Upstairs
 
 
 
 
2=LOW   3=HIGH  #=STAT 
 
 
To set a temperature setpoint, press 2 (HEAT) or 3 (COOL). 
 
For Celsius temperatures, press the ' # ' key prior to entering the temperature to make the number negative.  The Celsius 
temperature may also be specified in 0.5 degree steps if three numeric digits are entered.  The third digit adds a .5 to the first two 
digits if it is any- thing other than zero.  Enter a leading zero if necessary. 
 
In additions to setpoint changes, an energy saver may be turned On or Off.  It may also be turned On or Off for a specific 
duration. 
 
To turn the energy saver Off, select 0 (OFF).  To turn the energy saver On, select 1 (ON).  To turn the energy saver On or Off for 
a specific duration, select 9 (TIME) prior to selecting On or Off.  Enter the time as described under Control - Unit Commands. 
 
Page 33