Honeywell Work Light DR4300 User Manual

Page of 262
DR4300 Circular Chart Recorder 
114 
DR4300 Circular Chart Recorder Product Manual 
12/03 
4.3.19  Display Parameter Set Up Group 
Introduction  
Using the BLANK function, the display can be set to turn off a configured number of seconds after the last 
press of any key. Pressing any key while the display is blank will restore it.  
When the TOGGLE function is enabled, the pen currently driving the display will switch control to the 
other pen after a configured timeout period. If the other pen has its TOGGLE function enabled, it will 
switch back after its configured timeout period. 
 
Lockout group prompts 
Table 4-17 lists the function prompt in the lock out set up group. 
For a 2-pen recorder, the desired input channel is displayed on the left side of the operator interface. Press 
FUNC  to select channel. 
Press SETUP  key until “DSPLAY” appears in the lower display. 
Press FUNC  key to select the parameter. 
Table 4-17  Display Parameter Definitions 
Lower Display 
Prompt 
Upper Display  
Range of Setting  
or Selection 
Parameter  
Definition 
BLANK
 
OFF [factory setting] 
2s 
4s 



30s 
BLANKING FUNCTION
—Use this parameter to set 
timeout period after which the display goes blank. OFF 
disables the function. 
TOGGLE 
OFF [factory setting] 
2s 
4s 



30s 
TOGGLE FUNCTION
—Use this parameter to set the 
timeout period after which control the display is passed to 
the other board (pen).