Honeywell Work Light DR4300 User Manual

Page of 262
DR4300 Circular Chart Recorder 
168 
DR4300 Circular Chart Recorder Product Manual 
12/03 
7.3.5  Troubleshooting Erratic Pen Movement 
Procedure 
Table 7-5 explains what to do if the pen remains at the high end of range when the input signal is low.  
 
Table 7-5  Troubleshooting Erratic Pen Movement Symptoms 
Step 
What to do 
How to do it or  
where to find the instructions 
Check the sensor and lead wires for 
continuity. Check the connections to TB2 
on the printed circuit assembly for the pen 
with the problem. 
Replace the sensor lead wires as needed. 
Tighten the connections. 
Check the pen and input configuration 
data. 
Refer to Section 3 – Configuration, Startup, and 
Operation of Recorder without Display.
 
Run step test. 
Refer to Section 3 – Configuration, Startup, and 
Operation of Recorder without Display 
(Subsection 3.3.3).
 
Replace the servo plate assembly. 
Refer to the replacement procedure in Section 9 
– Replacing Hardware Assemblies.
 
Replace the printed circuit assembly for 
the pen having the problem. 
Refer to the replacement procedure in Section 9 
– Replacing Hardware Assemblies.