Honeywell Work Light DR4300 User Manual

Page of 262
DR4300 Circular Chart Recorder 
214 
DR4300 Circular Chart Recorder Product Manual 
12/03 
C.3  Drawing a Ramp/Soak Profile 
Ramp/soak profile example 
Before you perform the actual configuration, we recommend that you draw your Ramp/Soak profiles in the 
space provided on the blank graphs and fill in the associated information on the worksheet. An example of 
a Ramp-Soak Profile using the first twelve segments for Program 1 is shown in Figure C-1.  Start setpoint 
in this example is at 200 
°F. 
 
 
 
 
 
 
 
Figure C-1  Ramp/Soak Profile Example 
Prompt Function Segment  Value 
Prompt Function Segment  Value 
START1 
Start Seg. 
 
 
SG6 SP 
Soak SP 
250 
END 1 
End Seg. 
 
12 
 
SG6 TI 
Soak Time 
3 hr:0 min 
RECYCL 
Number of 
Recycles 
 2 
 
SG7 RP 
Ramp  
2 hr:30 min 
SOKDEV 
Deviation Value 
 
 
SG8 SP 
Soak SP 
500 
RP UNIT 
Ramp Units 
 
TIME 
 
SG8 TI 
Soak Time 
0 hr:30 min 
END ST 
Program 
State at end 
 HOLD 
 
SG9 RP 
Ramp  
SG1 RP 
Ramp  
1 hr 
 
SG10SP 
Soak SP 
10 
400 
SG2 SP 
Soak SP 
300 
 
SG10TI 
Soak Time 
10 
0 hr:30 min 
SG2 TI 
Soak Time 
1 hr:30 min 
 
SG11RP 
Ramp  
11 
3 hr:30min 
SG3 RP 
Ramp  
1 hr 
 
SG12SP 
Soak SP 
12 
200 
SG4 SP 
Soak SP 
400 
 
SG12TI 
Soak Time 
12 
0 hr:30 min 
SG4 TI 
Soak Time 
1 hr 
 
 
 
 
SG5 RP 
Ramp  
1 hr:30 min.