Hitachi GR2000 User Manual

Page of 410
Product Overview
GR2K-GA-1002
2-29
Rev 6.03
2.4.1
Cabinet (Network Processor Unit Chassis)
Each model of the GR2000 family has its own cabinet that includes one or more fans
for cooling. See Figures 2-1 thru 2-24 in 2.2 for their external images.
2.4.2
Basic Control Unit (BCU)
The components of the BCU vary depending on the GR2000 models as shown below.
Table 2-2
Each cabinet and maximum number of modules that can be mounted Device
Cabinet
Device
cabinet
Constituting element
Maximum number of
modules that can be
mounted
Remarks
GR2000-2S
BCU (RM-CPU and RMP)
1 (Built in. )
Corresponding to RP-A1.
1 (Built in. )
NIF
2
PS
1 (Built in. )
GR2000-4S
BCU (RM)
1
RP
1
NIF
4
PS
2
Possible of duplication.
GR2000-6H
BCU (RM and CSW)
2
Possible of duplication.
RP
3
NIF
6
PS
2
Possible of duplication.
GR2000-10H
BCU (RM and CSW)
2
Possible of duplication.
RP
5
NIF
10
PS
4
GR2000-20H
BCU (RM)
2
Possible of duplication.
CSW
2
Possible of duplication.
RP
10
NIF
20
PS
6
Possible of duplication.
Table 2-3
Abbreviation for BCU model names and configuration of each device
Device cabinet
Abbreviation for
BCU model name
Configuration
GR2000-2S
Built in cabinet
RM-CPU(2S) board
RMP boards (to handle RM-IO, RP-A1, 10BASE-T/
100BASE/TX (4 boards) are built in).
GR2000-4S
BDU-S300S
RM-CPU (4S) board
RM-IO (4S) board
GR2000-6H
BCU-H300H
RM-CPU (HH) board
RM-IO (H) board (Built-in 4x4 cross bar switch)
BCU-H850H
RMB-CPU (HH) board
RMB-IO (H) board (Built in 4x4 cross bar switch)