Henny Penny BM-110 Leaflet

Page of 2
       Model BM-110
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
POWER SWITCH
1. Remove screws holding base cover to unit and remove.
2. Remove the switch mounting nut, locknut, and the ON/OFF
plate, and remove the switch.
3. Place wires on new switch exactly as they were on the old
switch.
4. Replace mounting nut, ON/OFF plate, and locknut, then
tighten.
LARGE SPROCKET
1. Remove screws holding base cover to unit and remove.
2. Using a 1/8” Allen wrench, remove outer aluminum wheel and
spacer from drive shaft.
3. Remove master link from chain and remove chain.
4. Slide drive shaft out and using a 3/32” Allen wrench, loosen
set screws and remove large sprocket from drive shaft.
5. Replace large sprocket and assemble by reversing the
above order.
Install new sprocket on drive shaft at the same location
as old sprocket.
SMALL SPROCKET
1. Remove screws holding base cover to unit and remove.
2. Remove master link from chain and remove chain.
3. Using a 3/32” Allen wrench, loosen set screw and remove
small sprocket from motor.
4. Install new sprocket to motor.
MOTOR
1. Remove screws holding base cover to unit and remove.
2. Loosen wire nut from motor wires and remove motor wires.
3. Using a 3/8” wrench and a Phillips head screwdriver, remove
four screws and nuts holding motor to base.
4. Install new motor.
5. Place old fan blade on new motor.
Be sure motor wires are secure in wire nut.  Use
electrical tape to hold nut.
2