GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page of 74
DIAGNOSTIC STATUS CODES 
TRANSISTOR PUMP CONTROL 
 
 
Page  52 
January 2000
 
 
 
PUMP   
STATUS CODE
 
DESCRIPTION OF STATUS
 
CAUSE OF STATUS INDICATION
 
-180 
Voltage at capacitor (1C) is less than 
14 volts. 
This status code will be displayed when the voltage at 
P1 is less than 14 volts.  This occurs typically in the run 
mode of operation. 
MEMORY RECALL  
NO
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
SYMPTOM 
Pump control will not operate. 
 
POSSIBLE CAUSE 
(Line contactor controlled by traction 
control). 
Line Contactor opened up during run. 
= Check connection from P17 to Line 
coil (-) for loose connection. 
= Check connection from battery (+) to 
Line coil (+) for loose connection.  
= Check power connection from battery 
(+) to contactor L. 
= Check for blown fuse at pump control. 
= Check for dirty contactor tips. 
 
 
POWER
CONNECTIONS
POS
A1
NEG
A2
FI
EL
D
ARMATURE
+
-
FU1
FU3
KEY SWITCH
P1
P2
P3
P12
LINE
FU6
P19
P21
TO
TRACTION
CARD
SPEED L
IMI
T 1
SPEED L
IMI
T 2
SPEED L
IMI
T 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11
 
 
PUMP   
STATUS CODE
 
DESCRIPTION OF 
STATUS
 
CAUSE OF STATUS INDICATION
 
-181 
Battery voltage is less than 14 
volts.
 
This status code will be displayed when the battery voltage 
measured at P1 is less than 14 volts.
 
MEMORY RECALL  
NO
 
CORRECTIVE ACTIONS 
TROUBLE-SHOOTING DIAGRAM 
 
Circuits valid 
for  
Pump 
Controller 
 
 
SYMPTOM 
Pump control will not operate. 
 
POSSIBLE CAUSE 
= Defective control fuse. 
Check control fuse for open circuit, 
replace fuse, if necessary. 
= Check connection from control fuse to 
pump P1 for loose connections. 
 
POWER
CONNECTIONS
POS
A1
NEG
A2
FI
EL
D
ARMATURE
+
-
FU1
FU3
KEY SWITCH
P1
P2
P3
P12
LINE
FU6
P19
P21
TO
TRACTION
CARD
SPEED L
IMI
T 1
SPEED L
IMI
T 2
SPEED L
IMI
T 3
TO TRACTION
P10 - BDI
PY7
PY12
PY10
PY11