Gaggenau RB 472 User Manual

Page of 104
9
Aligning the appliance
To ensure that the appliance functions correctly, it must 
be set level with a spirit level.
If the appliance is not level, water may flow out of the ice 
maker, ice cubes may be irregular or the doors may not 
close properly.
Electrical connection
ã
WARNING
– Avoid the risk of an electric shock!
– Insert into a grounded 3-phase socket. 
Never remove grounding phase. Do not use any 
adapters. Do not use any extension cables.
– Non-compliance with these instructions may 
result in death, fire or an electric shock. 
Improper connection of the protective 
conductor may result in an electric shock. If you 
are in doubt whether the appliance has been 
grounded properly, have the appliance tested 
by a qualified electrician or service technician. 
The socket must be near the appliance and also freely 
accessible following installation of the appliance. 
The appliance complies with protection class I. 
Connect the appliance to 115 V/60 Hz alternating 
current via a correctly installed socket with protective 
conductor. The socket must be fused with a 10 to 16 A 
fuse. 
The appliance comes with a UL registered 3-wire power 
cord. The appliance requires a 3-pole socket. Please 
observe the following table with regard to this: 
Check on the rating plate whether the indicated voltage 
and current type correspond with the values of your 
power supply. The location of the rating plate can be 
found in the chapter entitled Customer service. 
ã
WARNING
Never connect the appliance to electronic energy 
saver plugs. Our appliances can be used with 
mains and sine-controlled inverters. Mains-
controlled inverters are used for photovoltaic 
systems which are connected directly to the 
national grid. Sine-controlled inverters must be 
used for isolated applications (e.g. on ships or in 
mountain lodges) which are not connected 
directly to the national grid.
Water connection
ã
CAUTION
Connect the appliance to a drinking water line.
The water may be connected only by a competent fitter 
according to the local regulations of the appropriate 
water supply company. 
A cold water connection is necessary for operating the 
automatic ice maker. The water pressure must be 
between 25 and 120 p.s.i. (1,72 and 8,25 bar). 
The installation must correspond to the local plumbing 
regulations. 
A separate shut-off valve should be installed in the cold-
water inflow. The shut-off valve should not be located 
behind the appliance. It is recommended that you mount 
the shut-off valve directly next to the appliance or at 
another place which is easily accessible. When installing 
the water connection, pay attention to the permissible 
installation area for the water mains. 
For connection to the drinking water mains use only 
water pipes which are suitable for drinking water. 
Observe national regulations and the connection 
conditions of the local water supply companies. 
When installing the water connection, observe the 
permitted installation areas for the pipe. For the 
permitted installation areas and dimensions see 
“Dimensions of the installation niche”.
The maximum outside diameter of the water mains 
(without connecting pieces) is 
3
/
8
" (9.5 mm).
Appliance
Maximum simultaneous 
load
Fridge-Freezer combination 
30" (75.6 cm) 
6.0 amps
Fridge-Freezer combination 
36" (90.3 cm) 
6.0 amps